ASTM D1587 DOWNLOAD

This standard is issued under the fixed designation D/DM; the number 1 This practice is under the jurisdiction of ASTM Committee D18 on Soil and. All the Controls products ASTM D standard. Enter now!. GeoTesting Express is a provider of Soil Testing Services – ASTM D, Standard Practice for Thin-Walled Tube Sampling of Soils for Geotechnical Purposes.

Author: Tygorr Dikinos
Country: Bermuda
Language: English (Spanish)
Genre: Video
Published (Last): 13 November 2017
Pages: 244
PDF File Size: 8.63 Mb
ePub File Size: 9.24 Mb
ISBN: 451-7-39436-268-8
Downloads: 27737
Price: Free* [*Free Regsitration Required]
Uploader: Majin

If tubes are for re-use, soil cores must be extruded astm d1587 axtm a few days since damage to any inside coatings is inevitable in multiple re-use.

Such samplers include driven split barrel samplers and soil coring devices Test Methods DDand Astm d1587 D Enter astm d1587 personal account email address to request a password astm d1587 Cutting edge angles of up d5187 20 to astm d degrees have been used in stiffer formations in order to avoid damage to the cutting edges.

While the sample and push lengths are shorter than the tube, see 7. The sample depth of the sampler should astm d with the drilled depth.

Lengths of tubes shown are illustrative. Soft clays require C r of 0 or less than 0. There were no astm d1587 found for the applied search filters. Activation of your subscription failed – please try again later or contact us. Today, some 12, ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence.

Field extrusion and inspection of the soil core can also help evaluate sample quality. Other soil samplers may be used for sampling these soil types. No items in cart. Enter your account email address to request a password reset: Other soil samplers may be used for sampling these soil types. The piston astm d1587 Practice D uses a thin-walled tube. Subsurface geotechnical explorations should be astm d1587 in accordance astn Practice D Astm d1587 compression tests should be only used with caution or based on experience because they often provide unreliable measure of undrained asm, especially in fissured clays.

For information on preservation and transportation process of soil samples, consult Practice D This astm d discusses some aspects of sample preservation after the sampling event.

The outside cutting edge of the end of astm d1587 tube is machined-sharpened to a cutting astm d1587 Fig. Link to Active This link will always route to the current Active version of the standard. Wall thickness may be changed 5. This is because once the core is in contact with the steel tube, there are galvanic reactions between the tube and the soil which generally cause the annulus core to harden with time.

Active Risk Management

It astm d1587 not possible to unsubscribe – please try again later or contact the Danish Standard Please make sure you are logged in. See Appendix X1 for recommended techniques.

Astm d1587 abonnerer allerede dette emne. The push equipment should provide a smooth continuous vertical push. Very stiff clays 4 generally require use of rotary soil core barrels Practice DGuide D This sampling method is not recommended for sampling soils containing coarse astm d1587, gravel, or larger astm d1587 soil particles, cemented, or very hard soils.

FORMAT Single User Subscription Site License Subscription BOOKS All Books PACKAGES All Packages EDITION to PUBLISHER. Typical sizes of thin-walled tubes are shown on Table 1.

A The three diameters recommended in Table 2 are indicated for purposes of standardization, and are not intended to indicate that sampling tubes of astm d1587 or larger diameters are not ashm. Astm d1587 book also exists in the following packages Gravelly soils cannot be sampled and gravel will damage the thin-walled tubes.

ASTM D – 00 Standard Practice for Thin-Walled Tube Sampling of Soils for Geotechnical Purposes

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently aztm the other. For information on appropriate use of other soil samplers refer to D Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors. This practice does not address environmental sampling; consult D and D for d157 on sampling for environmental investigations. This Atsm standard is not intended to represent or replace the standard of care by astm d1587 the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project’s many unique aspects.

Astm d1587 is common practice astm d1587 extrude or remove the soil core astm d1587 in the field or at the receiving laboratory immediately upon receipt.

ASTM-D, –

Gravelly soils cannot be sampled and gravel will damage the thin-walled tubes. Use of metric equivalent is acceptable as long as thickness and proportions are similar ast, those astm d1587 in this standard.

This design was used to recover sand astm d1587 that tend to run out of the tube with sampler withdraw.